Manager - HVAC
GMR Power Urban Infra · Hyderabad · onsite · Posted 2d ago
Undisclosed11–16 yrsfulltimeSourced from
About a minute. You'll make an account on the way through.
About this role
JOB PURPOSE
The role is responsible for overseeing a team of engineers and technical support specialists in the implementation of Mechanical systems works like HVAC systems in design, planning, project management,testing and commissioning during project while adhering to safety quality standards within cost and time
ORGANISATION CHART
Specialist Mechanical --> Manager Mechanical
KEY ACCOUNTABILITIES
Responsibilities
Key Performance Indicators (KPIs)
Maintenance Contract Management
- Monitor contract and SLA compliance for HVAC, Fire Protection, PHE, and BMS systems, focusing on preventive maintenance, serviceability, and timely response.
- Facilitate availability of tools, spares, and consumables, and manage documentation such as testing reports and service records.
- % preventive maintenance adherence
- hour average fault response time
- % availability of critical tools and spares
Project Planning Improvement Execution
- Prepare BOQs, technical specifications, and approved makes; support new projects and improvement works, especially for retail shops and non-aero commercial areas.
- Execute and monitor CAPEX/OPEX activities, ensuring quality control and timely completion.
- % timely BOQ and specification submissions.
- % on-time project delivery.
- 0 non-compliances during QC checks
Performance Optimization Reporting
- Drive improvement initiatives including Kaizen, 5S, BLIP, and CIP; submit MIS reports and track energy and water performance against baseline data.
- Analyze complaints, perform RCA, and implement CAPA to reduce recurring issues.
- % energy saving vs. baseline annually
- % reduction in repeated complaints quarterly
Field Quality -Project
Prepare the Inspection Test Plan for various equipment s items. Review approve the supplier QCP, welding book, heattreatment procedures, hydro test procedure, PMI procedure NDE procedures and fan, pump performance mechanicalrun test procedure.
Review pump performance, mechanical run test procedure.
specifications
Health, Safety, Environment and Regulatory compliances
Ensure safety compliance during HVAC Design processes.
Assist and work with the management for the effectivedeployment of the safety policy and achievement of the safetyobjectives and targets goals..
Ensure safety compliance during HVAC Design processes.
Assist and work with the management for the effectivedeployment of the safety policy and achievement of the safetyobjectives and targets goals..
KEY ACCOUNTABILITIES - Additional Details
EXTERNAL INTERACTIONS
- OEMs like M/s Honeywell, DIAKIN, Carrier, JCI, Armstrong, Notifier, Stulz, Minimax and other vendors like M/s UDS, M/s. Brady Services, M/s. Shri Karni Electrotech , M/s DCS, M/s PCCL etc.
INTERNAL INTERACTIONS
- Procurement Contracts
- HR Compliance Team
- Procurement Contracts
- QSD
- IT
- Finance and Accounts
- Terminal Operations
- City Side management
- Security and vigilance
- Commercial
- Estate Management
- SV
FINANCIAL DIMENSIONS
- Opex Budget approved in AOP
- Capex Budget approved in AOP
OTHER DIMENSIONS
- Total Internal Maintenance team employee size up to 9-11 numbers (Terminal wise).
- Total External Maintenance team employee size up to 120-150 numbers (Terminal wise).
- HVAC system having Chiller Machine, CHWP,CDWP, SCHWP, AHUs, PAHU, Fans, Split AC, Cooling tower etc.
- Fire and PHE Pump House having Electrical driven heavy duty pumps, Diesel engine driven duty pumps, Jockey Pumps, Potable Flush Water Pumps(Hydro-pneumatic System), Sump pumps, Detectors, FACP, Sprinklers, Hydrants, Deluge Valve Stations etc
EDUCATION QUALIFICATIONS
- BE/B.Tech. - Mechanical Engineering
- 3 Yrs. Engg. Diploma - Mechanical Engineering
RELEVANT EXPERIENCE
- Experience of at least 9+ years for BE/B.Tech. with relevant experience in Mechanical Systems, specifically in HVAC High Side (Chillers, Cooling Towers, Pumps, etc.) along with Fire Detection Protection, PHE and HVAC low side.
- Experience of at least 11+ years for 3Yrs. Engg. Diploma. with relevant experience in Mechanical Systems, specifically in HVAC High Side(Chillers, Cooling Towers, Pumps, etc.) along with Fire Detection Protection, PHE and HVAC low side.
- Good Communications skills
COMPETENCIES
- Risk Management (Practitioner)
- HSE Systems Implementation (Proficient)
- Regulatory and Legal Compliances (Practitioner)
- Internal Process/SAP Knowledge (Proficient)
- Project Planning and Execution (Proficient)
- Mechanical Systems (Proficient)
- Cost Management and Optimization (Practitioner)
- Asset Life Cycle Management and Serviceability (Proficient)
- Process Optimization (Practitioner)
- Social Awareness
- Entrepreneurship
- Personal Effectiveness
- Problem Solving Analytical Thinking
- Planning Decision Making
- Capability Building
- Strategic Orientation
- Stakeholder Focus
- Networking
- Execution Results
- Teamwork Interpersonal influence
This job posting has been aggregated from external source. Role details, content, and availability are subject to change. Applicants are advised to confirm the latest information directly on the company website before applying.
Sourced from naukri
Skills
Field QualityChillerhseCapability Building5SCAPAEstate ManagementFire ProtectionBOQHvac DesignCooling TowerChillersDelugeAHUsBOQsHVACcompliancefinanceFinance And Accountscontract managementEntrepreneurship