Facility Executive Technical
Jones Lang Lasalle · Bengaluru · onsite · Posted today
Undisclosed4–11 yrsfulltimeSourced from
About a minute. You'll make an account on the way through.
About this role
Job Summary
Electrical / Power Quality
A. Power Quality, Distribution Reliability
B. UPS, Emergency Power Controls
C. Grounding, Bonding ESD
D. Maintenance, Monitoring Response
E. Safety Compliance (Electrical)
2) Facility Engineer - Mechanical / Process Utilities (Semiconductor Labs)
A. Cleanroom HVAC (Critical Environment)
B. Chilled Water / PCW
C. Ultra-Pure Water (UPW/DI) Wastewater
D. Compressed Air (CDA), Vacuum Inert Gases
E. Fire, Life Safety Exhaust/Ventilation
F. Maintenance, Monitoring Analytics (PPM)
Facility Engineer with below requirement.
Primary Objective: Ensure stable, spec-compliant utilities for process tools and cleanroom performance with high uptime and contamination control.
Electrical / Power Quality
A. Power Quality, Distribution Reliability
- Operate and maintain LT systems, transformers, LT panels, PDU/RPP, isolation transformers, and static transfer switches (STS).
- Ensure N+1 / 2N redundancy for critical loads (process tools, scrubbers, abatement, BMS, safety systems).
- Monitor harmonics (THD), transients, flicker, and EMI/RFI; implement filters/SPDs and isolation strategies for sensitive tools (litho, metrology).
- Perform load studies, phase balancing, and feeder capacity checks prior to tool hookups and expansions.
B. UPS, Emergency Power Controls
- Operate and maintain UPS (modular/N+1), battery strings, DG sets, AMF/ATS panels; test black start and autotransfer sequences.
- Periodic battery health tests (IR, discharge tests), UPS efficiency tuning, and firmware/config backup.
- Maintain Emergency Power Off (EPO) circuits, interlocks with gas monitoring systems, and fire alarm interfaces.
C. Grounding, Bonding ESD
- Maintain clean/technical grounds, separate from building ground; verify low-impedance paths and equipotential bonding for tools.
- Implement and audit ESD controls (SEMI S20.20 practices), wrist straps, surfaces, flooring resistance, and static-safe layouts in cleanroom and chase areas.
D. Maintenance, Monitoring Response
- Establish PM/CBM for panels, breakers, relays, STS, UPS, and IR thermography for hot spots.
- Trend Mtbf/mttr, create SPC charts for voltage, frequency, THD, and temperature rise.
- Lead RCA on trips/nuisance faults; implement corrective and preventive actions.
E. Safety Compliance (Electrical)
- Enforce LOTO, arc-flash boundaries, insulated tools, and PPE.
- Maintain single-line diagrams, relay settings, test reports (IR, ER), and statutory compliance under CEA Regulations, Indian Electrical Safety Rules, and local inspectorate requirements.
- Integrate BMS/EPMS alarms, define SOPs for emergency shutdowns and controlled restarts.
2) Facility Engineer - Mechanical / Process Utilities (Semiconductor Labs)
A. Cleanroom HVAC (Critical Environment)
- Operate and optimize MAUs/AHUs/FFUs, Hepa/ulpa filtration, pressurization cascades, temperature RH controls.
- Maintain ISO 14644 cleanroom classes; track particle counts, airflow, and room recovery times.
- Handle filter life-cycle management, leak tests (DOP/PAO), duct hygiene, and IAQ.
- Seasonal tuning of coils, economizer modes, and dew point management to prevent condensation in bays/chasers.
B. Chilled Water / PCW
- Operate chillers (centrifugal/screw), CTs, primary/secondary pumping, and PCW loops for tools.
- Maintain temperature stability, T, flow, and vibration on critical pumps; maintain N+1 for critical circuits.
- Water treatment: scaling/corrosion inhibitors, biocide control, blowdown optimization.
- Trending: SPC on supply temp, differential pressure, specific energy consumption.
C. Ultra-Pure Water (UPW/DI) Wastewater
- Manage rinse loops, sanitization schedules, and return/reclaim strategies (if applicable).
D. Compressed Air (CDA), Vacuum Inert Gases
- Operate oil-free compressors, dryers, and filtration to meet dew point and oil/particulate specs; maintain VMB/VMP pressures.
- Maintain central vacuum and dry pump systems for tools; plan overhauls, flushing, and pump swap programs with OEMs.
- Manage bulk/packaged nitrogen (N2), vacuum-jacketed lines (if LN2), and purges for tools and abatement.
E. Fire, Life Safety Exhaust/Ventilation
- Maintain process exhaust, toxic exhaust, and general exhaust with redundancy and failure interlocks.
- Coordinate with fire detection/suppression (VESDA, clean agent where applicable), and ensure SEMI s2/s6/s8/s18 oriented risk controls.
F. Maintenance, Monitoring Analytics (PPM)
- Create PM schedules for pumps, compressors, chillers, FFUs, filters, cabinets, scrubbers, UPW, and neutralization systems.
- Use BMS to alarm, trend, and report; deploy predictive maintenance (vibration, oil analysis, dew point trends).
- Maintain spares strategy for high-risk items (VFDs, AHU motors, pump seals, pH probes, sensors, HEPA/ULPA, MERV prefilters).
Sourced from naukri
Skills
DG SetsCompressorsATSCbmapache airflowCorrosionChemical HandlingChemistryboilerChange ControlCooling TowerChillersAnalyticsamcsAHUsbreakersCompressorductcomplianceCommercial Real EstateArtificial Intelligence
About JLL

Jones Lang Lasalle
Real Estate
11.4k+
employees
1999
27 years old
Mumbai, Maharashtra
India
₹6.8L PA avg
Avg at JLL
About
JLL is a global real estate services firm specialising in commercial property and investment management, providing services for real estate owners, occupiers and investors worldwide
Industries
Real EstateEngineering & Construction
Employee ratings
10 reviews
4.1/ 5
Culture
2.8
Career growth
2.4
Work-life
3.6
Employees rate it well for
Job Security41Overall Company41
Find them on